Replacement of the connection cable
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
, or
coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the letter 'N'
or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the letter 'L'.
It must always be connected to the network
phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
To replace the connection cable use
only H05V2V2-F T90 or equivalent
type. Make sure that the cable section
is applicable to the voltage load and
the working temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer than the
live and neutral wire (A).
AB
Warning! A cut off plug inserted
into a 13 amp socket is a serious
safety (shock) hazard. Ensure
that the cut off plug is disposed
of safely.
Important! The replacement of electric
cable must be carried out exclusively by
the service force centre or by personnel
with similar competencies, in accordance
with the current regulations.
Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 450 mm
30 mm
10 mm
3 mm
11 mm
11 mm
A
A
B
A) supplied seal
B) supplied brackets
Caution! Install the appliance
only on a worktop with flat
surface.
18 Hob user manual